SMART-X Integrated Injection Machine
- light weight
- portable
- 900 Watt power motor
- > 700 Bar
- can be controlled by one man only
- can be controlled remotely by remote control
- have a memory to keep the pressure
- LED display to used in dark places
- automatically stopped when the pressure exceed a specific value
- Compact & Sturdy Design
- Hose Set included
- Heavy duty for daily use
- Pressure gauge
- Recommended for beginners and injection pros
SMART-X AT VILLAGION METRO STATION
SMART-X Injection Demo
- 1-Appearance: Aluminum structure, modular design
2-Volume: 385mm length * 420mm height * 195mm width
3-Drive power: 220V、50HZ、26A、900W
4-Max pressure: 80Mpa / 12000psi / 680bar
5-Work pressure: 10-55MPa / 1450-7900psi / 100-550 bar
6-The Pressure adjustable Range
of Remote Control From 10MPa to 70 MPa7-Weight: 8 KG
8-Package: Carton.
- 1-Subways
2-Tunnels
3-Reservoirs
4-Underground structures
5-Hair-like cracks
6-Construction joints
7-Expansion joints
8-Site improvements
9-Harbor construction
10-Floor and other upgrading works
-
- If there is no pressure or the pressure is too low, it may cause by
1) The in and out material system is block up by solid particles.
2) There is sand or remain curing material in the piston or piston fix part.
Method to work out
A) for situation1:
just cleansing the block
B) for situation 2:
open the three pcs screw of piston fix, clean the steel ball and spring Or just replace them. Notice, when fasten the screw, make sure fasten it at average level for the total 3 pcs. And please do not open other fix screws .
- Pressure adjustable Valve is plugged up, it may cause by not totally cleaned or there are solid particles in
- Just replace it. Notice, clean the machine in time